The Merge4 Platform

Solid-state power, modular by design

Power that senses, learns and acts. Two standalone products and one complete solution, in DC and AC: the Merge4 Node, the Merge4 Panel and the Merge4 Power Row.
Cabinet
600 kW
Per Merge4 Panel, in a standard OCP rack
Intelligent
200 kHz
Monitoring on every circuit
Power Row
1, 2.5 or 5 MW
Per Power Row
AC and DC
AC and 800 VDC
DC from H1 2027. AC from H2 2027.
AC and DC

One platform, in the power your site runs on.

DC
Merge4 DC
Available from H1 2027
Up to 800 VDC from source to rack. Solar and batteries are already DC, so a DC power train connects them without extra conversions. Compatible with OCP Diablo 400.
Talk to us about solar and storage
AC
Merge4 AC
Available from H2 2027
Drops into the AC facilities you run today, with the same Nodes, Panels and physical AI platform. The speed and intelligence of Merge4, without changing your power train.
Talk to us about AC
What we mean by solid state

Protection built on transistors.

Merge4 builds overcurrent protection on silicon carbide transistors, the technology that transformed computing and telecom. Protection acts in microseconds on every circuit.

Unlike a solid-state transformer, Merge4 works downstream in the distribution layer, at every node.

Product flow

One Node. Three products. The same power train at any scale.

Every Merge4 product starts with the Merge4 Node. Nodes build the Panel, Panels build the Power Row, and rows repeat across your campus. One power train runs from source to server rack, in DC or AC, from a single rack to a gigawatt.

Build your own sidecar with Nodes, or start with a complete Power Row. Add rows as load grows.

Merge4 Node modules
01 MODULE
Merge4 Node
Intelligent overcurrent protection for every circuit
Merge4 Panel cabinet
02 CABINET
Merge4 Panel
Monitors, protects and distributes power in one cabinet
Merge4 Power Row
03 ROW
Merge4 Power Row
One power train, from power source to server rack
Module

Merge4 Node

Where the intelligence starts.

The Merge4 Node is overcurrent protection built on computer chips. For the first time, you can see inside the power layer: each Node monitors every circuit in real time at 200 kHz, with no extra hardware. Transistors act 10,000x faster than mechanical levers, and each Node acts on what it sees, circuit by circuit, without waiting for a remote controller. Physical AI turns that data into operational intelligence. Designed for build-your-own-sidecar applications and compatible with OCP Diablo 400. Available in DC and AC.

SiC transistor-based power distribution with series air-gap galvanic isolation
Programmable current limiting and supplemental fault interruption
On-module anomaly detection and advisory
Hot-swappable for service on a live row
Cabinet

Merge4 Panel

Monitoring, protection and distribution in one standard OCP rack.

Conventional distribution splits the job in two: a PDU in one part of the data center and an RPP near the racks. The Merge4 Panel does both in one standard OCP rack beside the IT racks, delivering up to 600 kW. Every output is independently monitored, protected and controlled. Add Panels as load grows, up to multiple gigawatts, all on one connected Merge4 Platform. Protection holds 98% of its rating, against 80% for legacy protection.

Built-in 200 kHz monitoring at every circuit, no extra hardware
Fully metered outputs: V, I, P, energy, ripple and temperature
98% usable power rating against 80% for legacy protection
Safe-off default on every output on loss of control power
System

Merge4 Power Row

From power source to server loads: one end-to-end solution.

The Merge4 Power Row delivers power from source to server rack in one solution. In DC configurations it removes three of five conversion stages, packs more capacity into less space and monitors every channel.

Traditional power distribution creates heat, and heat drinks water. The Power Row runs more efficiently, so it sheds less heat and needs less cooling. Rows deliver 1, 2.5 or 5 MW and scale to gigawatts, in new builds or beside existing infrastructure. We supply one-line diagrams and commissioning support, so your team builds from a finished design, not a parts list.

Power Row schematic
Power source through DC UPS and Merge4 Panels to server racks. DC configuration shown.
UTILITY GRIDExisting infrastructureTRANSFORMER480 VAC 3-phase480 VACMERGE4 POWER ROWUPSMERGE4 PANELStandard OCP rackServer 01Server 02Server 03Server 04SERVER ROWStandard OCP racks
UTILITY GRIDExisting infrastructureTRANSFORMER480 VAC 3-phase480 VACMERGE4 POWER ROWUPSMERGE4 PANELStandard OCP rackServer 01Server 02Server 03Server 04SERVER ROWStandard OCP racks
Deployment

Nobody should have to choose between what they have and what comes next.

01
Expansion Row
At existing facilities
Add capacity beside what you run, without touching the existing power train.
02
Upgrade
At existing facilities
Replace legacy distribution in place, in AC or DC up to 800 VDC.
03
Greenfield
At new facilities
Design the whole power train from day one, on-site solar and batteries included, and commission it as one system.